09.01.2020

Keyence Kv Series Plc User Manual

61

Get all KEYENCE manuals! Sign up to create an account Facebook Twitter. By clicking Create Account, you agree to the Company’s. Status Modules (IV series → PLC). Keyence KV series. A-2 Description of the reference program. Get KEYENCE Visual KV Series User Manual. Get all KEYENCE manuals! Sign up to create an account Facebook Twitter. Terminal layout, circuit diagrams, and dimensions of the KV-16 x x. 1.5.1 Part Names and Functions. 1.5 KV-16AR/AT(P)/DR/DT(P) (16-I/O Basic Unit).

KEYENCE IV Series User Manual. Rockwell automation plc, Omron plc, List of supported plcs -4, Keyence plc -4, Kv series -4, Rockwell automation plc -4, Omron plc -4. KEYENCE Sensors. Manuals Directory ManualsDir.com - online owner manuals library.

- IV Series User’s Manual (Field Network) -
Chapter 4 PROFINET

Models in KV-7000 series by KEYENCE Singapore: Cable, CPU unit, Expansion unit, Extension unit, Interface unit, Memory card, Other option, Power supply unit, Software, Temperature and voltage measurement unit, Terminal block unit. Models in KV-5000/3000 series by KEYENCE India: Cable, Console, CPU unit, Expansion unit, Extension unit, External memory, I/O unit, Interface unit, Manual, Memory card, Other option, Power supply unit, Software, Temperature and voltage measurement unit, Terminal block unit. The NEW KV Series User’s Manual is composed of 3 separate manuals; 1-Installation, 2-Support Software, 3-Programming. Please read each manual relevant to your purpose.

Overview of PROFINET ...................4-2
What is PROFINET? ....................4-2
functions in the IV series ...................4-3
specications..........................4-3
the DCP protocol .......................4-3
functions in the IV series .................4-4
...................4-5
........................4-5
Phoenix Contact PLC ..................4-5
OMRON PLC ........................4-5
Overview of the data I/O communication.......5-2
What is data I/O communication? ..........5-2
Data I/O communication setting method .......5-3
Setting the IV series .....................5-3
When setting by IV-Navigator (IV-H1) ......5-4
Setting the device name..................5-5
When setting by IV-Navigator (IV-H1) ......5-5
PLC settings ...........................5-6
Setting the Siemens TIA Portal ...........5-7
Data allocations in
the data I/O communication................5-16
Control Modules (PLC → IV series) ........5-16
Command Control ................5-16
Status Modules (IV series → PLC) ........5-17
Command Status Bits .............5-17
Device Result Bits ................5-17
Device Status Words .............5-18
Device Statistics .................5-18
Tool Result Modules (IV series→ PLC) .....5-19
Position Adjust Result .............5-19
Tool Result .....................5-19
Control Modules parameter details ........5-20
Command Control Address 0 to 1:
Control request ..................5-20
Command Control Address 2 to 3:
Handshake control ...............5-21
Command Control Address 4 to 11:
Program No. ....................5-21
Status Modules parameter details.........5-22
Command Status Bits Address 0:
Control result (response) ..........5-22
Command Status Bits Address 1:
Control error result ...............5-22
Command Status Bits Address 2 to 3:
..5-23
Device Results Bits Address 0 to 3:
Status result ....................5-25
Device Status Words
Error/status/status result information

(Statistics information) ............5-27
Tool Result Modules parameter details .....5-28
Position Adjust Result
(Position correction information) .....5-28
Tool Result Address 0 to 19
(Tool information) ................5-28
Error code list .........................5-29
Warning code list ......................5-30
the data I/O communication................5-32
the IV series
(Handshake control [Disabled]) ...........5-32
When a trigger is successful ........5-32
When a trigger is unsuccessful ......5-33
the IV series
(Handshake control [Enabled])............5-34
Switching the programs in the IV series .....5-35
the IV series externally ..................5-36
Reference program (EtherNet/IP)............A-2
............. A-2
Keyence KV series ...................A-2
Description of the reference program
Rockwell Automation PLC

..A-3
.............A-4
Keyence KV series ...................A-4
Description of the reference program
Rockwell Automation PLC ..............A-5
Description of the reference program
Program switching......................A-6
...................A-6
Description of the reference program
Rockwell Automation PLC ..............A-7
Description of the reference program
Reference program (PROFINET)
Handshake control [Disabled] ............. A-8
Siemens PLC ........................A-8
Description of the reference program
Handshake control [Enabled]
Siemens PLC
........................A-9
Description of the reference program
Program switching.....................A-10
.......................A-10
Description of the reference program
Index
.................................A-12

Page 22: Rockwell automation plc, Omron plc, List of supported plcs -4, Keyence plc -4, Kv series -4, Rockwell automation plc -4, Omron plc -4

Advertising

2-4

- IV Series User’s Manual (Field Network) -

EtherNet/IP communication specifications and functions in the IV series

List of supported PLCs

Keyence Programming Manual

Check the instruction manual of each PLC for details of the setting methods.

Keyence PLC

z

Mobi thermometer instructions 70119

„

KV series

PLC model

EtherNet/IP

communication unit

Firmware

version

Software used

Version of the

software used

KV-3000

KV-EP21V

Ver.2 or later

KV STUDIO

Ver.6.0 or later

KV-5000

KV-EP21V

Ver.2 or later

KV-5500

-

(Built-in port or KV-

EP21V)

Ver.2 or later

Rockwell Automation PLC

PLC model

EtherNet/IP

communication unit

Firmware

version

Software used

Version of the

software used

1756 ControlLogix

1756-ENBT

1756-EN2T

Ver.13 or later

RSLogix5000

Ver.13 or later

1769 CompactLogix - (Built in the unit)

Plc

Ver.13 or later

OMRON PLC

PLC model

EtherNet/IP

communication unit

Firmware

version

Software used

Version of the

software used

SYSMAC CJ2

-

(Built-in port or

CJ1W-EIP21)

V1.0 or later

CX-One

Ver.3.0 or later

SYSMAC CJ1

CJ1W-EIP21

V1.0 or later

SYSMAC CS1

CJ1W-EIP21

V1.0 or later

2

EtherNet/IP

Kv Studio Keyence

Advertising

Keyence Plc Programming

Popular Brands

Keyence Manual Pdf

Popular manuals